Search
Filters

Fusion Bonded Epoxy Coatings (FBE) and Disbondment

In this paper, failure analysis methodology will be applied to the principal mechanisms by which FBE coatings fail during long term service; with specific application to case studies involving blistering. The case studies apply standard failure analysis techniques to determine the primary causes and modes of failures.

Product Number: 51316-7246-SG
ISBN: 7246 2016 CP
Author: Mehrooz Zamanzadeh
Publication Date: 2016
$0.00
$20.00
$20.00

Fusion Bonded Epoxy (FBE) coating has been used for corrosion protection of underground pipe lines since the 1960’s. FBE provides protection of pipeline under cathodic protection even though there may be dis-bondment or blistering. FBE does not shield cathodic protection current under normal conditions, a characteristic which likewise distinguishes FBE coating from all other coating. In this paper failure analysis methodology will be applied to the principal mechanisms by which FBE coatings fail during long term service; with specific application to case studies involving blistering. The case studies apply standard failure analysis techniques to determine the primary causes and modes of failures. Solution in blistered areas, pH and presence of cations and chlorides on the surface and in the coating will provide evidence for surface contamination/dis-bondment mechanism. If AC interference or shielding is present, localized corrosion attack in blistered areas can be detected prior to deep penetration in to wall thickness by effective corrosion monitoring. This can be achieved by on-time monitoring of soil corrosivity and AC/DC interference by test coupons.

 Keywords: Corrosion Protection, Pipeline, Coating, Fusion Bonded Epoxy Coatings (FBE), Blistering, Coating Failure Mechanism, Cathodic Protection, AC Interference, DC stray Current Corrosion, Shielding.

Fusion Bonded Epoxy (FBE) coating has been used for corrosion protection of underground pipe lines since the 1960’s. FBE provides protection of pipeline under cathodic protection even though there may be dis-bondment or blistering. FBE does not shield cathodic protection current under normal conditions, a characteristic which likewise distinguishes FBE coating from all other coating. In this paper failure analysis methodology will be applied to the principal mechanisms by which FBE coatings fail during long term service; with specific application to case studies involving blistering. The case studies apply standard failure analysis techniques to determine the primary causes and modes of failures. Solution in blistered areas, pH and presence of cations and chlorides on the surface and in the coating will provide evidence for surface contamination/dis-bondment mechanism. If AC interference or shielding is present, localized corrosion attack in blistered areas can be detected prior to deep penetration in to wall thickness by effective corrosion monitoring. This can be achieved by on-time monitoring of soil corrosivity and AC/DC interference by test coupons.

 Keywords: Corrosion Protection, Pipeline, Coating, Fusion Bonded Epoxy Coatings (FBE), Blistering, Coating Failure Mechanism, Cathodic Protection, AC Interference, DC stray Current Corrosion, Shielding.

Also Purchased
Picture for 00166 INFLUENCING FACTORS IN CATHODIC DISBONDMENT
Available for download

00166 INFLUENCING FACTORS IN CATHODIC DISBONDMENT OF FUSION BONDED EPOXY COATINGS

Product Number: 51300-00166-SG
ISBN: 00166 2000 CP
Author: Rafael E. Rodriguez , Brenda L.Trautman , and Joe H. Payer
$20.00
Picture for 00757 FBE, a Foundation for Pipeline Corrosion
Available for download

00757 FBE, a Foundation for Pipeline Corrosion Coatings

Product Number: 51300-00757-SG
ISBN: 00757 2000 CP
Author: J. Alan Kehr and David G. Enos